An on-grid inverter’s main job is to convert DC power generated from the PV array into usable AC power. Hybrid inverters go a step further and work with batteries to store excess power as well. In the developing world, hybrid inverters are more of a necessity to compensate for weak or intermittent grids or a lack of grid electricity all together.
An on-grid inverter’s main job is to convert DC power generated from the PV array into usable AC power. Hybrid inverters go a step further and work with batteries to store excess power as well. In the developing world, hybrid inverters are more of a necessity to compensate for weak or intermittent grids or a lack of grid electricity all together.
Model | GSL-29.9KHV-3PH | GSL-30KHV-3PH | GSL-35KHV-3PH |
GSL-40KHV-3PH | GSL-50KGV-3PH |
Battery Input Data | |||||
Battery Type |
Li-Ion | ||||
Battery Voltage Range (V) | 160~800 | ||||
Max.Charging Current (A) |
50+50 | ||||
Max.Discharging Current (A) |
50+50 | ||||
Number of Battery Input |
2 | ||||
Charging Strategy for Li-on Battery |
Self-adaption to BMS | ||||
PV String Input Data | |||||
Max.DC Input Power (W) | 38870 | 39000 | 45500 | 52000 | 65000 |
Max.DC Input Voltage (V) | 1000 |
||||
Start-up voltage (V) | 180 | ||||
MPPT Range (V) | 150-850 |
||||
Rated DC Input Voltage (V) | 600 |
||||
Max. Operating PV Input Current (A) | 36+36+36 | 36+36+36+36 | |||
Max. Input Short-Circuit Current (A) | 55+55+55 | 55+55+55+55 | |||
No.of MPPT Trackers/ No.of String Per MPPT Tracker |
3/2+2+2 | 4/2+2+2+2 |
|||
AC Output Data | |||||
Rated AC Output and UPS Power (W) | 29900 | 30000 | 35000 |
40000 | 50000 |
Max. AC Output Power (W) | 29900 |
33000 | 38500 | 44000 |
55000 |
AC Output Rated Current (A) | 37.9/36.3 | 45.5/43.5 | 53.1/50.8 | 60.7/58 | 75.8/72.5 |
Max. AC Output Rated Current (A) | 45.4/43.4 | 50/43.5 | 58.4/55.8 | 66.7/63.8 | 83.4/79.7 |
Max. Three-phase Unbalanced Output Current (A) | 60 | 60 | 60 |
70 | 83.3 |
Max. Continuous AC Passthrough (A) | 200 | ||||
Peak Power (off grid) | 1.5 time of rated power, 10 S | ||||
Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | ||||
Rated Input/Output Voltage/Range (V) | 220/380V, 230/400V 0.85Un-1.1Un | ||||
Rated Input/Output Grid Frequency/Range(Hz) | 50/45-55, 60/55-65 | ||||
Grid Connection Form | 3L+N+PE | ||||
Total Current Harmonic Distortion THDi | <3% (of nominal power) | ||||
DC Component of Grid | <0.5% In | ||||
Efficiency | |||||
Max. Efficiency |
97.60% |
||||
Euro Efficiency | 97.00% | ||||
MPPT Efficiency | 99.00% | ||||
Equipment Protection | |||||
Integrated | DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch Overvoltage Load Drop Protection, Residual Current (RCD) Detection, Surge protection level | ||||
Surge Protection Level | TYPE II(DC), TYPE II(AC) | ||||
Interface | |||||
Communication Interface | WIFI, RS485, CAN | ||||
General Data | |||||
Operating Temperature Range(℃) | -40~60℃, >45℃ derating | ||||
Permissible Ambient Humidity | 0-100% | ||||
Permissible Altitude | 2000m | ||||
Noise | ≤65 dB(A) | ||||
Ingress Protection(IP) Rating | IP65 | ||||
Inverter Topolog | Non-Isolated | ||||
Over Voltage Category | OVC II(DC), OVC III(AC) | ||||
Cabinet Size (WxHxD mm) | 527×894×294 (Excluding Connectors and Brackets) | ||||
Weight (kg) | 80 | ||||
Type of Cooling | Intelligent Air Cooling | ||||
Warranty |
5 Years/10 Years the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy |
||||
Grid Regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 | ||||
Safety / EMC Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |