High Voltage Mini ESS 50kwh 80/100/120/130kwh
Model:GSL-BESS-50K80/GSL-BESS-50K100/GSL-BESS-50K120/GSL-BESS-50K130
Battery Chemistry: LifePO4 battery
Voltage:51.2v/48V
Life Cycles:6500 Cycles
The Mini C&I Energy Storage System is a fully integrated, pre-configured solution for LargeResidential and Light Commercial Projects (3Ph 220/380, 230/400Vac @60Hz). The Mini C&I ESS has numerous applications such as Microgrid, backup, off-grid peak shaving, time of use, self-supply, demand response, and Virtual Power Plant (VPP). With AC and DC Coupling options, indoor and outdoor installation, and Scalable capacity from 80-130kWh per unit, the Mini C&IESS is perfect for your project.
50kWh 80/100/120/130kWh High Voltage Energy Storage System(ESS)
1. Solution for Fast Install
Fully integrated, pre-configured package system reduces on-site installation time; includes inverter(s), battery trays, racks, BMS, Microgrid Controller, HVAC, fire suppression, islanding switch, and outdoor rated enclosure.
2. Easy & Flexible to Scale
The modular design allows for easy capacity expansion.
The rack-mounted design allows for installation in various settings, A single system can be expanded up to 130kWh.
3. Safe Technology & Multi-level Protection
Tier 1LiFePO4 Phosphate chemistry for the highest level of safety, thermal stability, and reliability; An integrated, multi-level Battery Management System(BMS) monitors, optimizes, and balances the system.
4. Powerful Performance
Supports a rated DC power of 130kW. It can handle charge/ discharge currents of 50A(recommended), 100A(nominal), and up to 125A peak discharge for 2 minutes at 25°℃.
Model No | GSL-BESS-50K80 | GSL-BESS-50K100 |
GSL-BESS-50K120 | GSL-BESS-50K130 |
System Specification | ||||
Nominal Output Power/UPS Power (W) | 5000 | |||
AC Output Frequency and Voltage
|
50/60Hz; 3L/N/PE 220/380, 230/400Vac | |||
Grid Type | Three phase | |||
Energy Configuration (kWh)
|
81.92 | 102.4 |
122.88 |
133.12 |
Dimension (W x D x H,mm) |
1400x1100x1650 (no contain inverter)
|
|||
Weight Appr. (kg) (no contain inverter) |
969.6
|
1172.0 |
1294.4 |
1375.6 |
AC Output Rated Current (A) | 100 | |||
Battery Operating Voltage (V) | 500~800 |
|||
Battery Chemistry | LiFePO4 |
|||
IP Rating of Enclosure | IP55 |
|||
System Certification | UN38.3, IEC62619, CE, CEI 0-21, VDE-AR-N 4105, IEC 62109 | |||
Installation Style | Floor-Mounted | |||
Warranty | 10 years | |||
Inverter Technical Specification | ||||
Max. PV Input Power (W) |
65000
|
|||
Max. PV Input Current (A) | 36+36+36+36 | |||
Rated PV Input Voltage (Vdc) | 600 | |||
Start Up DC Voltage (Vdc) | 180 | |||
MPPT Voltage Range (Vdc) |
150~850 | |||
Max. PV Short-circuit Current (A) | 55+55+55+55 | |||
Number of MPPT | 4 | |||
Peak Power (off grid) | 1.5 time of rated power, 10s | |||
Power Factor | 0.8 leading to 0.8 lagging | |||
THD | <3% | |||
DC injection current (mA) | <0.5ln | |||
Display | LCD | |||
Operating Temperature Range (℃) | -40~60( >45℃ derating) | |||
Relative Humidity | 15% ~ 85% (No Condensing) | |||
Dimension (W x D x H, mm) | 527x294x894 (Excluding Connectors and Brackets) | |||
Inverter Communication |
CAN, RS485, WIFI, ETH | |||
Safety EMC / Standard | IEC/EN 62109-1, IEC/EN 62109-2, IEC/EN 61000-6-1, IEC/EN 61000-6-2, IEC/EN 61000-6-3, IEC/EN 61000-6-4 | |||
Grid Regulation | VDE4105, IEC61727/62116, VDE0126, AS4777.2, CEI 0 21, EN50549-1, G98, G99, C10-11, UNE217002, NBR16149/NBR16150 | |||
Max. Efficiency | 97.60% |
|||
Max. Charging/Discharging Efficiency |
91.00% | |||
Max Parallel connection sets | 10 |
|||
Battery Technical Specification | ||||
Battery Module Nominal Voltage (V) | 409.6 | 512 |
614.4 |
665.6 |
Battery Capacity (Ah) | 200 | |||
Battery Energy (kWh) | 81.92 | 102.4 |
122.88 |
133.12 |
BMS Communication | CAN | |||
BMS parallel support connection | 3sets(Standard), 32 sets ( Extra BAU module) | |||
Max Charge & Discharge Current (A) | 100 |
|||
Operating Temperature Range | Charge: 0~55℃ / Discharge: -20℃~55℃ | |||
Cycle Life | ≥6500(@25℃±2℃,0.5C/0.5C,70%EOL) | |||
Short Circuit Protection | YES |
|||
Over Current Protection | YES | |||
Over Charge Protection | YES | |||
Over Temperature Protection | YES | |||
Cell Over Voltage Protection | YES | |||
Cell Over Under Protection | YES | |||
Cell Discharge Protection | YES |