Three Phase Hybrid Inverter GSL-6/8/10/12/15KHV-3PH-EU
100% unbalanced output, each phase; Max. output up to 50% rated power
DC couple and AC couple to retrofit existing solar system
Max. 16pcs parallel for on-grid and off-grid operation; Support multiple batteries parallel
Max.charging/discharging current of 37A
High voltage battery, higher efficiency
6 time periods for battery charging/discharging
Support storing energy from diesel generator
Model |
GSL-10KHV-3PH |
GSL-15KHV-3PH |
GSL-20KHV-3PH |
Battery Input Data |
Battery Type
|
Li-Ion |
Battery Voltage Range (V) |
160~700 |
Max.Charging Current (A) |
37 |
Max.Discharging Current (A) |
37 |
Number of Battery Input |
1 |
Charging Strategy for Li-on Battery |
Self-adaption to BMS |
PV String Input Data |
Max.DC Input Power (W) |
13000 |
19500 |
26000 |
Max.DC Input Voltage (V) |
1000 |
Start-up voltage (V) |
180 |
MPPT Range (V) |
150-800 |
Full Load DC Voltage Range (V) |
325-850 |
420-850 |
500-850 |
Rated DC Input Voltage (V) |
600 |
PV Input Current (A) |
20+20 |
26+20 |
26+26 |
Max. PV I SC (A) |
30+30 |
39+30 |
39+39 |
No.of MPPT Trackers |
2 |
No.of Strings Per MPPT Trackers |
1 |
2+1 |
2 |
AC Output Data |
Rated AC Output and UPS Power (W) |
10000 |
15000 |
20000 |
Max. AC Output Power (W) |
11000 |
16500 |
22000 |
AC Output Rated Current (A) |
15.2/14.5 |
22.8/21.8 |
30.4/29 |
Max. AC Output Rated Current (A) |
16.7/16 |
25/24 |
33.4/31.9 |
Max. Three-phase Unbalanced Output Current (A) |
22 |
30 |
35 |
Max. Continuous AC Passthrough (A) |
40 |
80 |
Peak Power (off grid) |
1.5 time of rated power, 10 S |
Generator input/Smart load /AC couple current (A) |
15.2/40/15.2 |
22.8/80/22.8 |
30.4/80/30.4 |
Power Factor |
0.8 leading to 0.8 lagging |
Output Frequency and Voltage |
50/60Hz; 3L/N/PE 220/380, 230/400Vac |
Grid Type |
Three Phase |
DC injection current (mA) |
<0.5%1n |
Efficiency |
Max. Efficiency |
97.60%
|
Euro Efficiency |
97.00% |
MPPT Efficiency |
99.90% |
Protection |
Integrated |
PV Input Lightning Protection, Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection, Surge protection |
Output Over Voltage Protection |
DC Type II/AC Type III |
Certifications and Standards |
Grid Regulation |
VDE4105, IEC61727/62116, VDE0126, AS4777.2, CEI 0 21, EN50549-1, G98, G99, C10-11, UNE217002, NBR16149/NBR16150 |
Safety EMC / Standard |
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
General Data |
Operating Temperature Range(℃) |
-25~60℃,>45℃ Derating |
Cooling |
Smart cooling |
Noise (dB) |
<45 |
Communication with BMS |
RS485;CAN |
Weight (kg) |
30.5 |
Size (W*H*D) |
408×638×237mm |
Degree |
IP65 |
Installation Style |
Wall-mounted |
Warranty |
5 years |