An on-grid inverter’s main job is to convert DC power generated from the PV array into usable AC power. Hybrid inverters go further and work with batteries to store excess energy. In the developing world, hybrid inverters are more of a necessity to compensate for weak or intermittent grids or a lack of grid electricity altogether.
Three Phase Hybrid Inverter GSL-6/8/10/12/15KHV-3PH-EU
100% unbalanced output, each phase; Max. output up to 50% rated power
DC couple and AC couple to retrofit existing solar system
Max. 16pcs parallel for on-grid and off-grid operation; Support multiple batteries parallel
Max.charging/discharging current of 37A
High voltage battery, higher efficiency
6 time periods for battery charging/discharging
Support storing energy from diesel generator
Model | GSL-10KHV-3PH | GSL-15KHV-3PH | GSL-20KHV-3PH |
Battery Input Data | |||
Battery Type |
Li-Ion | ||
Battery Voltage Range (V) | 160~700 | ||
Max.Charging Current (A) | 37 | ||
Max.Discharging Current (A) | 37 | ||
Number of Battery Input | 1 | ||
Charging Strategy for Li-on Battery | Self-adaption to BMS | ||
PV String Input Data | |||
Max.DC Input Power (W) | 13000 | 19500 | 26000 |
Max.DC Input Voltage (V) | 1000 | ||
Start-up voltage (V) | 180 | ||
MPPT Range (V) | 150-800 | ||
Full Load DC Voltage Range (V) | 325-850 | 420-850 | 500-850 |
Rated DC Input Voltage (V) | 600 | ||
PV Input Current (A) | 20+20 | 26+20 | 26+26 |
Max. PV I SC (A) | 30+30 | 39+30 | 39+39 |
No.of MPPT Trackers | 2 | ||
No.of Strings Per MPPT Trackers | 1 | 2+1 | 2 |
AC Output Data | |||
Rated AC Output and UPS Power (W) | 10000 | 15000 | 20000 |
Max. AC Output Power (W) | 11000 | 16500 | 22000 |
AC Output Rated Current (A) | 15.2/14.5 | 22.8/21.8 | 30.4/29 |
Max. AC Output Rated Current (A) | 16.7/16 | 25/24 | 33.4/31.9 |
Max. Three-phase Unbalanced Output Current (A) | 22 | 30 | 35 |
Max. Continuous AC Passthrough (A) | 40 | 80 | |
Peak Power (off grid) | 1.5 time of rated power, 10 S | ||
Generator input/Smart load /AC couple current (A) | 15.2/40/15.2 | 22.8/80/22.8 | 30.4/80/30.4 |
Power Factor | 0.8 leading to 0.8 lagging | ||
Output Frequency and Voltage | 50/60Hz; 3L/N/PE 220/380, 230/400Vac | ||
Grid Type | Three Phase | ||
DC injection current (mA) | <0.5%1n | ||
Efficiency | |||
Max. Efficiency |
97.60% |
||
Euro Efficiency | 97.00% | ||
MPPT Efficiency | 99.90% | ||
Protection | |||
Integrated | PV Input Lightning Protection, Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection, Surge protection | ||
Output Over Voltage Protection | DC Type II/AC Type III | ||
Certifications and Standards | |||
Grid Regulation | VDE4105, IEC61727/62116, VDE0126, AS4777.2, CEI 0 21, EN50549-1, G98, G99, C10-11, UNE217002, NBR16149/NBR16150 | ||
Safety EMC / Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | ||
General Data | |||
Operating Temperature Range(℃) | -25~60℃,>45℃ Derating | ||
Cooling | Smart cooling | ||
Noise (dB) | <45 | ||
Communication with BMS | RS485;CAN | ||
Weight (kg) | 30.5 | ||
Size (W*H*D) | 408×638×237mm | ||
Degree | IP65 | ||
Installation Style | Wall-mounted | ||
Warranty | 5 years |