Model |
GSL-29.9KHV-3PH |
GSL-30KHV-3PH |
GSL-35KHV-3PH
|
GSL-40KHV-3PH |
GSL-50KGV-3PH
|
Batareya kiritish maʼlumoti |
Batareya turi |
Li-Ion |
Batareya kuchlanish diapazoni (V) |
160 ~ 800 |
Zaryadlash oqimi (A)
|
50+50 |
Max.Tushirish oqimi (A)
|
50+50 |
Batareyani kiritish soni
|
2 |
Li-on batareyasini zaryadlash strategiyasi
|
BMSga o'z-o'zini moslash |
PV qatorini kiritish maʼlumotiName |
Max.DC kirish kuchi (Vt) |
38870 |
39000 |
45500 |
52000 |
65000
|
Max.DC kirish kuchlanishi (V) |
1000
|
Ishga tushirish kuchlanishi (V) |
180 |
MPPT diapazoni (V) |
150-850
|
Nominal DC kirish voltaji (V) |
600
|
Amaliy PV kirish oqimi (A) |
36+36+36 |
36+36+36+36 |
kirish qisqa tutashuv oqimi (A) |
55+55+55 |
55+55+55+55 |
MPPT kuzatuvchilari soni/
MPPT kuzatuvchisi uchun soni
|
3/2+2+2 |
4/2+2+2+2
|
ACning chiqish maʼlumoti |
Nominal AC chiqishi va UPS quvvat (Vt) |
29900 |
30000 |
35000
|
40000 |
50000 |
AC chiqish kuchi (Vt) |
29900
|
33000 |
38500 |
44000
|
55000
|
AC chiqish nominal oqim (A) |
37.9/36.3 |
45.5/43.5 |
53.1/50.8 |
60.7/58 |
75.8/72.5 |
AC chiqish nominal oqimi (A) |
45.4/43.4 |
50/43.5 |
58.4/55.8 |
66.7/63.8 |
83.4/79.7 |
uch fazali muvozanatsiz chiqish oqimi (A) |
60 |
60 |
60
|
70 |
83.3
|
Max. uzluksiz AC o'tish (A) |
200 |
Eng yuqori quvvat (tarmoqdan tashqari) |
nominal kuch 1,5 marta, 10 S |
Quvvat omilini sozlash oralig'i |
0.8 0.8 kechikishga olib keladi |
Nominal kiritish / chiqish kuchlanish / diapazon (V) |
220/380V, 230/400V 0.85Un-1.1Un |
Nominal kirish / chiqish Grid chastotasi / diapazon (Hz) |
50/45-55, 60/55-65 |
Tarmoqqa ulanish shakli |
3L + N + PE |
Umumiy joriy garmonik buzilish THDi |
<3% (of nominal power) |
Toʻrning DC komponentiComment |
<0.5% In |
Mahsuldorlik |
Maks. |
97.60% |
Evro samaradorligi |
97.00% |
MPPT samaradorligi |
99.00% |
uskunalar himoya qilish |
Ulangan |
DC qutblanish teskari ulanish himoyasi, AC chiqishi haddan tashqari oqim himoyasi, AC chiqishi haddan tashqari kuchlanishni himoya qilish, AC chiqishi qisqa tutashuvi himoyasi, issiqlik muhofazasi DC terminal izolyatsiya empedansini monitoring qilish, DC komponentlarini monitoring qilish, tuproq xatosi oqimini monitoring qilish quvvat tarmog'ini monitoring qilish, orolni himoya qilish monitoringi, er xatosini aniqlash, DC kirish kaliti haddan tashqari kuchlanish yukini pasaytirish himoyasi, qoldiq oqim (RCD) aniqlash, kuchlanish himoyasi darajasi |
Haddan tashqari himoya darajasi |
II TURI (DC), II TURI (AC) |
InterfeysStencils |
Aloqa interfeysi |
WIFI, RS485, MUMKIN. |
Umumiy maʼlumot |
Operatsion harorat oralig'i (°C) |
-40 ~ 60 °C, >45 °C tushirilishi |
Ruxsat etilgan muhit namlik |
0-100% |
Ruxsat etilgan balandlik |
2000 m |
Shovqin |
≤65 dB (A) |
Kirish himoyasi (IP) reytingi |
IP65 |
Inverter topologiyasiComment |
Izolyatsiya qilinmagan |
Kuchlanish toifasi |
OVC II (DC), OVC III (AC) |
Kabinetning o'lchami (GxHxD mm) |
527×894×294 (ulagichlar va qavslar bundan mustasno) |
Og'irligi (kg) |
80 |
sovutish turi |
Aqlli havo sovutish |
Kafolat |
5 yil / 10 yil
Kafolat muddati inverter yakuniy o'rnatish saytiga bog'liq, batafsil ma'lumot, kafolat siyosati bilan bog'laning
|
Tarmoqni tartibga solish |
IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 |
Xavfsizlik / EMC standarti |
IEC / EN 61000-6-1 / 2/3/4, IEC / ENG 62109-1, IEC / ENG 62109-2 |